UPDATED [Jul 28, 2022] Pass NetApp Certified Support Engineer Exam with Latest Questions [Q20-Q36]

Share

UPDATED [Jul 28, 2022] Pass NetApp Certified Support Engineer Exam with Latest Questions

NS0-194 Exam Practice Questions prepared by Network Appliance Professionals

NEW QUESTION 20
How many drive bays does a DS4246 shelf have?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

 

NEW QUESTION 21
Click the Exhibit button at the right.
When using ONTAP, the customer uses a mirror-SnapVault cascade, as shown in the exhibit. The Snapshot copies successfully transfer from the primary volume on storage system A to the SnapMirror destination on storage system B.
However, not all SnapMirror Snapshot copies are being transferred from storage system B to the XDP destination on storage system C.

In this scenario, which Snapshot copies will transfer successfully?

  • A. transfers initiated by a SnapMirror schedule
  • B. only Snapshot copies with the SnapMirror label called sm_created
  • C. all manually initiated SnapMirror transfers
  • D. any Snapshot copy created within the last 24 hours

Answer: B

 

NEW QUESTION 22
A customer has reported an unexplained reboot of an ONTAP node that did not generate a panic string or a core file.
In this scenario, which two sets of logs do you collect to further diagnosis the issue? (Choose two.)

  • A. events all
  • B. sp status -d
  • C. system core
  • D. sp status

Answer: A,C

 

NEW QUESTION 23
In ONTAP 9.5, the event log show command queries and displays entries from which file?

  • A. messages.log
  • B. ems.log
  • C. bcomd.log
  • D. mgwd.log

Answer: B

 

NEW QUESTION 24
You are using AFF storage with the NVMe storage protocol on your Linux clients.
In this scenario, which NVMe feature must be present and enabled for the client to see storage failover happen?

  • A. Multi-Path I/O (MPIO)
  • B. Asymmetric Namespace Access (ANA)
  • C. NVMe Qualified Name (NQN)
  • D. Asymmetric Logical Unit Access (ALUA)

Answer: A

 

NEW QUESTION 25
Click the Exhibit button at the right.
When using ONTAP, the customer uses a mirror-SnapVault cascade, as shown in the exhibit. The Snapshot copies successfully transfer from the primary volume on storage system A to the SnapMirror destination on storage system B.
However, not all SnapMirror Snapshot copies are being transferred from storage system B to the XDP destination on storage system C.

In this scenario, which Snapshot copies will transfer successfully?

  • A. transfers initiated by a SnapMirror schedule
  • B. only Snapshot copies with the SnapMirror label called sm_created
  • C. all manually initiated SnapMirror transfers
  • D. any Snapshot copy created within the last 24 hours

Answer: B

 

NEW QUESTION 26
An administrator notices that the clustered Data ONTAP 8.2.3 controllers are less responsive than normal. You use On Command Performance Manager but do not see obvious problems, yet, this particular issue is constant. Users are starting to complain.
Which tool would you use to collect data to help diagnose this issue?

  • A. Perfstat
  • B. Auto Support
  • C. Perfmon
  • D. Performance Archive

Answer: C

 

NEW QUESTION 27



Which type of MetroCluster is shown in the exhibit?

  • A. 2-node stretch MetroCluster
  • B. 4-node Fabric-Attached MetroCluster
  • C. 4-node stretch MetroCluster
  • D. 4-node MetroCluster IP

Answer: B

 

NEW QUESTION 28
A disaster causes a FlexGroup volume to be unrecoverable, but it was protected by a SnapMirror relationship.
You solve the issue, and the source is operational. Now, you want to return to serving the data from the original source.
In this scenario, what do you do next?

  • A. Initialize the SnapMirror relationship.
  • B. Restore data from a backup copy.
  • C. Perform a SnapMirror update.
  • D. Delete the SnapMirror relationship.

Answer: A

 

NEW QUESTION 29
Referring to the exhibit.

A database administrator explains that the backup job scheduled to complete by 7:00 AM is not completing as fast as expected. You log in to theFAS3240 system and execute a few commands and obtain the output shown in the exhibit.
Which system resource would you eliminate as a eliminate as a problem based on the command output?

  • A. disk
  • B. CPU
  • C. memory
  • D. network

Answer: C

 

NEW QUESTION 30
In ONTAP 9.6, activity on the command line is found in which log?

  • A. audit.log
  • B. messages.log
  • C. command-history.log
  • D. mgwd.log

Answer: A

 

NEW QUESTION 31
A user on an NFSv4 client is listing a directory and sees the file in an is -1 listing shown below:
"rwr------1 nobody nobody 10767 Mar 24 2016 party.txt"
The customer would like to know why the user and group shows as "nobody".
Which statement would explain why this is happening?

  • A. There is an NFSv4 ID domain mismatch.
  • B. The file resides on an NTFS style volume.
  • C. There is no owner or group set on the file.
  • D. The permissions does not allow for listing the owner.

Answer: D

 

NEW QUESTION 32
Exhibit:

A customer receives the AutoSupport message shown below.
''(?] Sat Aug 23 13:00:27 PDT [hostname: env_rngr: callhome.c.fan.fru.fault:error] :
Call home for CHASSIS FAN FRU FAILED: SysFan3 F2 (?] Sat Aug 23 13:00:32
PDT [hostname: env_mgr: monitor.chassisFan.ok:notice]: Chassis fan Sysfan3 F2 is ok"
The output of the sysconfig -a command is shown in the exhibit.
In this scenario, what would you do to solve this problem?

  • A. Update Data ONTAP to 8.1.4 at the latest patch level.
  • B. Disconnect the controller from the mains, wait two minutes, and re-connect it in the next maintenance window.
  • C. Update the Service Processor firmware.
  • D. Replace the fan.

Answer: A

 

NEW QUESTION 33
Exhibit:








Which two steps would you perform to correct the problem shown in the exhibit? (Choose two.)

  • A. Reseat the shelf modules.
  • B. Replace the shelf chassis.
  • C. Reseat the power supplies.
  • D. Perform a takeover and giveback.

Answer: A,D

 

NEW QUESTION 34
Your Windows clients were able to access your CIFS SVM yesterday. Today they are no longer able to access the CIFS SVM on your NetApp cluster. Your IT security team just pushed out a new group policy to enhance security.
In this scenario, which statement is true?

  • A. Your CIFS SVM is not using DNS.
  • B. Your CIFS SVM is configured for NFSv3 access.
  • C. Your CIFS SVM is configured to use SMBv1 and SMBv2.
  • D. Your CIFS SVM is configured for the wrong domain.

Answer: A

 

NEW QUESTION 35
Click the Exhibit button at the right.
A customer reports that a node panicked due to a multidisk failure.
While in take over, the customer reviewed the output of the sysconfig -a command and noticed a discrepancy in the shelf stack as shown in the exhibit.

The customer proceeded to examine the power supplies in the stack of shelves; all were functional.
Which step would you take to solve this problem?

  • A. Replace the SAS cable from adapter 2d to shelf 1.
  • B. Replace the shelf chassis of shelf 1.
  • C. Replace the motherboard in the broken node.
  • D. Reseat all the disks in shelf 1.

Answer: B

 

NEW QUESTION 36
......

NS0-194 Exam Practice Materials Collection: https://examtorrent.actualcollection.com/NS0-194-exam-questions.html